NF ENERGY / EXCLUSIVE DC SELECTION

DC charging.
Power with purpose.

Exclusive commercial offering NF ENERGY exclusively markets the DC charging solutions from 60 to 360 kW presented on this page. A dedicated commercial approach for infrastructure where performance, customer experience and the installation context must work together.

Rated power figures from manufacturer documentation. Performance, configuration, compliance and availability require model-specific verification.

Manufacturer rendering: 360 kW DC charging station with two cables
360 kWRated DC power
60–240 kWModular DC charger family
360 kWRated ultra-fast output
200–1.000 VStated DC output voltage range
OCPP 1.6JStated communication protocol
Original photograph of electric bus depot with manufacturer chargersDocumentary photograph of a third-party charging installation

01 / The quality of the decision

Beyond power.
The value of context.

A DC charging station is part of a site’s identity, the quality of the user experience and the efficiency of its operations. Available grid capacity, vehicles, use patterns, software and site requirements guide the choice.

Through its exclusive commercial offering for the range shown here, NF ENERGY supports clients in identifying the configuration to be reviewed with the manufacturer and relevant technical specialists.

02 / Product technology

Two ranges.
A considered choice.

Specifications are drawn from product documentation. Equipment configurations, interfaces and conformity documentation must be checked for the actual model offered.

DC CHARGING / 60–240 KW SERIES
Original manufacturer visual of 60 to 240 kW DC fast charger range

60–240 kW

Compact DC chargers for public and professional use. RFID, QR code interface and integration with a charging management system are described in technical product documentation.

Rated power60 / 120 / 180 / 240 kW
DC output voltage200–1.000 V DC
Charging interfacesCCS1 / CCS2*
ProtocolOCPP 1.6J
Request information ↗
DC CHARGING / HIGH POWER
Original manufacturer render of 360 kW DC charger

360 kW DC

A higher-power solution for demanding sites. The product presentation describes convection cooling and a coupler-current boost mode.

Rated power360 kW
Coupler current350 A / 500 A boost*
DC output voltage200–1.000 V DC
ProtocolOCPP 1.6J
Request information ↗

* CCS1/CCS2 options and 500 A boost mode depend on the version/configuration. Real charging power and time also depend on the vehicle, battery, site and grid supply. Model-specific CE and metrology documents must be checked prior to a commercial offer.

03 / Integrated systems

Power and control.
Considered management.

The technology illustrated includes charging hardware, software components and remote diagnostic features for public charging and fleet applications.

01 / CSMS / OCPP

Charging management

Station status monitoring, charging session oversight and remote configuration functions described by the manufacturer.

02 / EMS / LOAD

Energy management

Dynamic power allocation, peak shaving and integration with other energy assets, subject to project design.

03 / DIAGNOSTIC

Diagnostics and monitoring

Operational parameter monitoring, anomaly alerts and maintenance support to improve charger availability.

04 / Documented applications

Technology at work.

The supplied technical materials illustrate international charging deployments for electric buses, public stations and integrated systems. These are third-party installations, not projects delivered by NF ENERGY.

Third-party manufacturer photograph of electric buses at a charging depot
Fleet depot · manufacturer case study
Third-party manufacturer photograph of public 180 to 360 kW charging equipment
Public DC charging · manufacturer case study

The photographs depict third-party applications in international settings. They are not NF ENERGY construction references or installations delivered by NF ENERGY in Italy.

05 / CSMS + EMS

A clearer view across the charging network.

The CSMS/EMS systems illustrated may support charger monitoring, power management and energy analytics, subject to the agreed equipment and software configuration.

Monitoring and dashboardsDynamic load managementAlerts and diagnosticsEnergy and operation reports

Third-party technical software screenshot for illustration; this is not NF ENERGY proprietary software.

Third-party manufacturer screenshot of manufacturer EMS energy management dashboard

06 / Applications

Every destination.
A tailored assessment.

From public high-turnover areas to planned depot charging, each deployment warrants a dedicated technical and economic evaluation.

01 / PUBLIC HUBS

Public hubs

Service areas, parking facilities and high-turnover public charging.

02 / FLEET & DEPOT

Fleet depots

Electric buses, commercial fleets and scheduled charging windows.

03 / RETAIL & LOGISTICS

Retail and logistics

Commercial parking, operating locations and logistics facilities.

04 / INTEGRATED ENERGY

Integrated energy

Potential architectures combining storage, solar generation and energy management, subject to assessment.

08 / A dedicated consultation

An important decision.
A private conversation.

Tell us about your location, available grid capacity, vehicles and operating objectives. NF ENERGY offers a dedicated commercial conversation to identify configurations for technical verification.

Infrastructure & Projects desk

NF ENERGY

DC charging systems, product configurations and availability:

progetti@nfenergy.eu+39 335 640 1728